SYSTEA MicroMac-1000 Nutrient Analyzer
Special adaption for mobile and offshore applications.
The µMAC-1000 is an on-line portable analyzer, available with sequential mutiparametric configuration, providing the highest level of analytical automation. The µMAC-1000 is the only high sensitivity multiparametric portable analyzer in the market; it uses the well known wet chemistry methods normally used in the laboratories. The analyzer can measure any type of water sample; a wide range of applications is available, including high sensitivity methods for nutrients analysis in seawater. Sample analysis is easy and friendly; it can perform very complex analytical cycles; the results are displayed in concentration units and provided through the analogue or the RS-232 port. At the end of each analytical cycle the analyzer remains in stand by mode, without reagents consumption, always ready for next sample. Dilution mode can be automatically activated on over range samples, with a dilution factor, factory selected, up to 100.
Portable, easy to install and to manage.
Fully automated operation; no operator required during operation.
Automatic calibration; it is enough to select the calibration function to perform a new calibration.
Results data storage; the analyzer can store up to 400 measuring results including date, time and optical density.
Remote control: via SmartDI™ Controller, digital contacts, RS-232 interface.
Short analyzing time: typ. 5-7min (depending on method).
Low detection limit: typ. 1ppb (depending on method).
Available for most of all nutrients.
Small form factor: 800 x 450 x 300mm, appr. 10kg (without eagents and tools).
Low power consumption: appr. 10W at analysis, 4W in stand-by.
Wide input voltage: 9-40V DC unregulated or 90-240V AC.
Improvements for autonomous operations.
Mobile high-performance Analyzers

Nutrient Analyzers System Tools and Setups
We provide our clients with the tools to operate the SYSTEA Nutrient Analyzers on Ships, Buoys and other challenging applications.
1. Get carefully the water from outside, without changing the nutrient concentrations.
2. Filter the water and prevent biofouling on the filters.
3. Use cooled long-time stable chemicals for approx. 6 weeks.
4. Control the anylyzer with a fail-safe software and react in cases of problems: SmartDI™ Controller.
5. Keep your waste water on-board for clean oceans.
6. Save the quality validated data and transmit them to your office for further processing.

0 comments: